Teleform - 'RLock timed out' Error

Teleform - 'RLock timed out' Error

The exact cause of this issue is unclear but has a known solution:

  1. Shutdown all modules and server modules

  2. Run 'Teleform Maintenance and Utility' on a workstation and run the 'Clear Lock Records' operation.

  3. Open License Service and client modules.

In most situations, restarting the offending modules resolves this issue, but when it doesnt, to force the removal of all temporary locks on the system, you'd run the Teleform Maintenance Utility on a workstation and run the Clear Lock Records operation as mentioned.

If you have further issues, contact OpenText support or CASO Support.

Related content

OTS - OutPut Transformation Server - Error - Unable to load XenosEngine.config
OTS - OutPut Transformation Server - Error - Unable to load XenosEngine.config
More like this
ApplicationXtender - License Service - License Error
ApplicationXtender - License Service - License Error
More like this
OTS - "ERROR :<Engine 16.1.37_5524> System initialization failed"
OTS - "ERROR :<Engine 16.1.37_5524> System initialization failed"
More like this
OTS - Output Transformation Server - Engine 20.4.12_9110 -String index out of range: 0...
OTS - Output Transformation Server - Engine 20.4.12_9110 -String index out of range: 0...
More like this
TeleForm - Internal Database Connection Information Change
TeleForm - Internal Database Connection Information Change
More like this
Teleform - Remote Capture Station Not Synchronizing Job Settings
Teleform - Remote Capture Station Not Synchronizing Job Settings
More like this

Copyright © CASO Document Management

All product names, logos, brands, and trademarks featured or referred to on this page are the property of their respective trademark holders. These trademark holders are not affiliated with, nor do they sponsor or endorse this website or the products/services offered unless explicitly stated otherwise.