ApplicationXtender Administrator- Viewing PID Table under monitoring section of Administrator causes an error: "Object reference not set to an instance of an object."
...
Applies to
- ApplicationXtender Desktop 16.3, 8.2
- ApplicationXtender License Server 16.3
- ApplicationXtender Web Access.NET 16.3, 8.1
Summary
In ApplicationXtender Administrator, and error occurs when clicking on PID table under Monitoring.
...
Refresh AX Administrator and the PID table should now be available going forward.
Warning: Only experienced Database Administrators should make modifications to the database. The result of an inexperienced user modifying the database could be disastrous.
CASO recommends backing up the production database before making modifications.